
New Publication !!!
Clarbruno Vedruccio e Carla Ricci Articoli
Noninvasive radiofrequency diagnostics of cancer. The Bioscanner ―Trimprob technology and clinical applications,
Journal of Physics: Conference Series, Vol. 329, 012038, 2011.
Relazione al 9th International Fr�hlich�s Symposium, Electrodynamic Activity of Living Cells (EDALC11) , Praga 2011.
http://iopscience.iop.org/1742-6596/329/1
online: LINK
Jiri Pokorny; Clarbruno Vedruccio; Michal Cifra, PhD.; Ondrej Kucera, Cancer physics: Diagnostics based on damped cellular elasto electrical vibrations in microtubules (European Biophysics Journal)
2011 March 10
online: LINK
|
|
|
Il 12 novembre a Portonovo (AN) ci sar� un convegno relativo al Bioscanner (tra i relatori: Clarbruno Vedruccio, Roberto Giacobbo e diversi medici utilizzatori).
Per maggiori info:
- evento fb: www.facebook.com/events/1811881029048794
- website: Registrati al Convegno
- brochure: Brochure Convegno
� aperto al pubblico fino alle 15,30 (evento gratuito). IN CORSO DI AGGIORNAMENTO
Info per commercializzazione: [email protected]
BIOSCANNER� TRIMPROB TM
|
Prodotto dalla Galileo Avionica S.p.A., distribuito dalla TrimProbe S.p.A. (ambedue del Gruppo Finmeccanica) fino a gennaio 2008 su licenza di utilizzo brevetto del dr. Clarbruno Vedruccio.
|
CARATTERISTICHE

Il Bioscanner� TRIMprob (Tissue Resonance Interaction Method probe) � un dispositivo diagnostico in possesso del marchio CE quale �sistema elettromedicale per la diagnostica non invasiva�; iscritto nel Repertorio dei Dispositivi Medici del Servizio Sanitario Nazionale.
|
Servizio Sanitario Nazionale Repertorio Dispositivi Medici (DM)
TRIMPROB Dispositivo Validato
|

|
Il dispositivo consiste in una sonda che, emettendo un campo elettromagnetico di esigua potenza, effettua un�analisi non invasiva dei tessuti che consente di rilevare la presenza di stati patologici (tra cui di particolare importanza le formazioni tumorali), e in un ricevitore che, mediante un programma software dedicato, consente di visualizzare l�interazione della sonda emettitrice con i tessuti e di registrare i test effettuati.
L�emissione elettromagnetica consiste nella generazione, con modalit� peculiari, di tre frequenze in banda UHF (intorno a 460, 920 e 1350 MHz), ognuna delle quali � associata all�eventuale risposta generata da tessuti di tipologia differente; in particolare, il segnale sulla prima frequenza interagisce con le formazioni tumorali evidenziando sul display del sistema un abbassamento della riga spettrale.

CERTIFICAZIONI

Risultati dei principali studi clinici col Bioscanner � TRIMprob� pubblicati
Organo
|
N� pazienti
|
Sensibilit�
%
|
Specificit�
%
|
Valore Predittivo Positivo (P.P.V)
|
Valore Predittivo Negativo (N.P.V.)
|
Accuratezza
%
|
ARTICOLI SCIENTIFICI
|
PROSTATA
|
|
|
|
|
|
|
|
1- Prof. Scialpi M, Prof. Vedruccio C.
(HSS Annunziata Taranto)
|
43
|
94
|
92
|
|
96
|
93
|
Nuove possibilit� diagnostiche tramite onde elettromagnetiche (Fisica in medicina 2004)
|
2 � Dr. Bellorofonte C et Al.
(HSCarlo � Milano)
|
757
|
95
|
43
|
94
|
90
|
|
Non-invasive detection of prostate cancer by electromagnetic interaction
(European Urology, Jan. 2005)
|
3 � Dr. Da Pozzo L et Al.
(Studio multricentrico in cinque Univ.: S.Raffaele � Mi, Federico II NA, Careggi FI, S.Orsola-Malpighi BO, Cattinara Trieste)
|
188
|
80
|
51
|
44
|
84
|
60
|
Tissue-resonance interaction method for the non-invasive diagnosis of prostate cancer: analysis of a multicentre clinical evaluation
(BJU Int, Nov. 2007)
|
4 - Prof. Tubaro A et Al.
(HSAndrea � Univ.Roma)
|
111
|
86
|
63
|
60
|
88
|
72
|
The electromagnetic detection of prostatic cancer: evaluation of diagnostic accuracy
(Urology, Aug. 2008)
|
5 - Dr Gokce O et Al.
(Dip. Urologia �Univ. Istanbul)
|
148
|
76
|
61
|
40
|
89
|
|
TRIMprob has the potential to be used alongside the recognized tests in the screening protocols for prostate cancer
(Int J Urol, Jun. 2009)
|
6 - Prof. Cerulli, dr.Di Viccaro et Al (Univ.Umberto I� Roma)
|
782
|
(with PSA>4ng/ml)
84,1
|
(with PSA>4ng/ml)
67,8
|
(with PSA>4ng/ml)
61,7
|
(with PSA>4ng/ml)
83,8
|
|
The accuracy of tissue resonance interaction method probe (Trimprob tm) in non-invasive diagnosis of prostatic cancer. Analysis of the result of 782 patients (Urologia 2009)
|
VESCICA
|
|
|
|
|
|
|
|
7 - Dr. Leucci, Prof Vedruccio
(H. Vito Fazzi � Lecce)
|
114
|
87,5
(Cohen�s K = 0.77)
|
90,5
(P < 0.001)
|
83,3
|
91,1
|
89,5
|
Diagnosis of bladder cancer at 465 MHz.
(Electromagn Biol Med, 2007)
|
7.1 - Prof. Cormio et Al.
|
125
|
97,9
|
89,9
|
86,8
|
98,6
|
93,6
|
"Non-Invasive Electromagnetic Detection of Bladder Cancer," ISRN Urology, vol. 2014, Article ID 802328, 4 pages, 2014. doi:10.1155/2014/802328. Link
|
SENO
|
|
|
|
|
|
|
|
8 - Dr. Paganelli, dr. De Cicco C(I.E.O. � Milano)
9 - Dr. Carrozza, Prof.Vedruccio(Oncologia Medica Ospedale Umberto I, Lugo - Ravenna)
|
101
180
|
84
|
75
(p<0.001)0,90/0,97
|
|
80
|
72
|
Clinical application of spectral electromagnetic interaction in breast cancer: diagnostic results of a pilot study(Tumori, 2006)
Breast Cancer Diagnosis Possibility By Means Of Vedruccio�s Non-Linear Resonance Interaction Scanner (TRIMprob) (2007)
|
TIROIDE
|
|
|
|
|
|
|
|
10 - Prof. Sacco R et Al.
(Clinica Chir. �Univ Catanzaro)
|
51
|
100
|
100
|
|
|
100
|
Preoperative diagnosis of incidental carcinoma in multinodular goitre by means of electromagnetic interactions
(Chir Ital, Apr. 2007)
|
STOMACO - DUODENO
|
|
|
|
|
|
|
|
11 - Prof Vedruccio C/ Prof. Mascia E et Al
(Clinica Chir. Osp MM- Taranto)
|
45
|
93
|
93
|
95
|
92
|
|
Ultra high frequency and microwave non-linear interaction �
(Inter Rev Armed Forces Med Services 2005)
|
12 - Prof. Sacco R et Al.
(Clinica Chir. � Univ Catanzaro)
|
43
|
100
|
100
|
|
|
100
|
Relief of gastric cancer with an electromagnetic interaction system (TRIMprob) in outpatients (Chir Ital, Dec. 2007)
|
RETTO
|
|
|
|
|
|
|
|
13 - Prof. Leo, dr. Vannelli A et Al. (INT � Milano)
Risultati preliminari (2009)
14 - Risultati completi (2010)
|
228
442
|
94
94
|
85
84
|
86
92
|
93
88
|
89
90
|
Diagnosis of rectal cancer by electromagnetic interactions: preliminary results (Dis Colon Rectum, Jan 2009)
Diagnosis of rectal cancer by Tissue Resonance Interaction Method, BMC Gastroenterology 2010, 10:45
|
COLON
|
|
|
|
|
|
|
|
15 - Dr. Marcello Tufano, dr. Dore et Al. (Univ. Sassari)
|
121
|
100
|
100
|
|
|
100
|
C.Vedruccio-C.Ricci, Non invasive radiofrequency diagnostics of cancer. The Bioscanner-Trimprob technology and clinical applications, Journal of Physics: Conferences Series 329 (2011) 012038
|
16 - Dr. Marcello Tufano, dr. Dore et Al. (Univ. Sassari)
|
305
|
99
|
91
|
92
|
99
|
100
|
ACCURACY OF DIAGNOSTIC BIOSCANNER TRIMprob, NON INVASIVE METHODS IN SEARCH OF THE COLON PRE-CANCEROUS LESIONS. DOUBLE BLIND-STUDY (publication in progress)
|
|
Tot. 3.784
|
|
|
|
|
|
Link per la visualizzazione degli articoli scientifici:
1 - Nuove possibilit� diagnostiche tramite onde elettromagnetiche (Fisica in medicina 2004)
http://clarbrunovedruccio.it/doc/Fisica%20in%20Medicina%202004.pdf
2 - Non-invasive detection of prostate cancer by electromagnetic interaction (European Urology, Jan. 2005)
http://www.ncbi.nlm.nih.gov/pubmed/15582246
3 - Tissue-resonance interaction method for the non-invasive diagnosis of prostate cancer: analysis of a multicentre clinical evaluation (BJU Int, Nov. 2007) http://www.ncbi.nlm.nih.gov/pubmed/17711511
4 - The electromagnetic detection of prostatic cancer: evaluation of diagnostic accuracy (Urology, Aug. 2008)
http://www.ncbi.nlm.nih.gov/pubmed/18336888
5 - TRIMprob has the potential to be used alongside the recognized tests in the screening protocols for prostate cancer (Int J Urol, Jun. 2009) http://www.ncbi.nlm.nih.gov/pubmed/19456986
6 - The accuracy of tissue resonance interaction method probe (Trimprob tm) in non-invasive diagnosis of prostatic cancer. Analysis of the result of 782 patients (Urologia 2009)
http://www.ncbi.nlm.nih.gov/pubmed/21104675
7 - Diagnosis of bladder cancer at 465 MHz. (Electromagn Biol Med, 2007)
http://www.ncbi.nlm.nih.gov/pubmed/17613039
8 - Clinical application of spectral electromagnetic interaction in breast cancer: diagnostic results of a pilot study (Tumori, 2006)
http://www.ncbi.nlm.nih.gov/pubmed/16869237
9 - Breast Cancer Diagnosis Possibility By Means Of Vedruccio�s Non-Linear Resonance Interaction Scanner (TRIMprob) (2007)
http://www.icems.eu/docs/venice/6th_Workshop_Carrozza.pdf
10 - Preoperative diagnosis of incidental carcinoma in multinodular goitre by means of electromagnetic interactions (Chir Ital, Apr. 2007)
http://www.ncbi.nlm.nih.gov/pubmed/17500182
11 - Ultra high frequency and microwave non-linear interaction � (Inter Rev Armed Forces Med Services 2005)
12 - Relief of gastric cancer with an electromagnetic interaction system (TRIMprob) in outpatients (Chir Ital, Dec. 2007)
http://www.ncbi.nlm.nih.gov/pubmed/18360987
13 - Diagnosis of rectal cancer by electromagnetic interactions: preliminary results (Dis Colon Rectum, Jan 2009)
http://www.ncbi.nlm.nih.gov/pubmed/19273973
14 - Diagnosis of rectal cancer by Tissue Resonance Interaction Method, BMC Gastroenterology 2010, 10:45
http://www.biomedcentral.com/1471-230X/10/45
15 - C.Vedruccio-C.Ricci, Non invasive radiofrequency diagnostics of cancer. The Bioscanner-Trimprob technology and clinical applications, Journal of Physics: Conferences Series 329 (2011) 012038
http://iopscience.iop.org/1742-6596/329/1/012038
16 - ACCURACY OF DIAGNOSTIC BIOSCANNER TRIMprob, NON INVASIVE METHODS IN SEARCH OF THE COLON PRE-CANCEROUS LESIONS. DOUBLE BLIND-STUDY http://clarbrunovedruccio.it/doc/Poster%20dr%20Tufano%202012%20lesioni%20precanc%20Colon.pdf
|

STUDIO COMPARATIVO TEST CON BIOSCANNER TRIMPROB E ALTRI PARAMETRI DIAGNOSTICI SINGOLI O ASSOCIATI
Andrea Tubaro, Cosimo De Nunzio, Alberto Trucchi,Antonella Stoppacciaro e Lucio Miano, The Electromagnetic Detection of Prostatic Cancer: Evaluation of Diagnostic accuracy, Urology 72(2)340-4.
PARAMETRI |
SENS |
SPEC |
VPP |
VPN |
ACC |
PARAMETRI SINGOLI |
|
|
|
|
|
TRIMROB |
86 |
63 |
60 |
88 |
72 |
PSA TOT |
90 |
16 |
41 |
73 |
45 |
FREE/TOT |
78 |
34 |
35 |
72 |
50 |
DRE |
40 |
88 |
69 |
69 |
69 |
TRUS |
36 |
79 |
69 |
48 |
55 |
COIN TOSS
(TESTA o CROCE)
|
45 |
54 |
36 |
63 |
55 |
|
|
|
|
|
|
PARAMETRI ASSOCIATI |
|
|
|
|
|
TRIMPROB + DRE |
96 |
57 |
59 |
95 |
72 |
PSA TOT + DRE |
96 |
13 |
42 |
82 |
46 |
FREE/TOT PSA + DRE |
81 |
53 |
51 |
82 |
64 |
SENS: sensibilit� (la percentuale di soggetti veramentente malati positivi al test, cio� quanto il risultato positivo indica l�effettiva presenza di malattia);
SPEC: specificit� (la percentuale di sogg sani negativi al test, cio� quanto il risultato negativo indica la effettiva assenza di malattia);
V.P.P. Valore Predittivo Positivo (la probabilit� che un sogg positivo al test sia veramente malato); V.P.N. Valore Predittivo Negativo (la probabilit� che un sogg negativo al test sia veramente sano); ACC: accuratezza (la percentuale di diagnosi corrette).
DRE: digital rectal examination (esplorazione digito rettale); TRUS: transrectal ultrasaund (ecografia transrettale); Coin toss: testa o croce.
DIFFUSIONE
ITALIA
Il TRIMprob trova al momento consolidata applicazione per la prostata e per la vescica. Il test � attualmente effettuabile presso una cinquantina di centri pubblici e/o privati in varie regioni italiane.
Una ventina di sistemi sono attualmente presenti in alcuni paesi esteri. Tra questi:
Francia, Belgio, Svezia, Brasile, Malesia, Iran, Giappone, Turchia.
PRODUZIONE E DISTRIBUZIONE
Prodotto dalla Galileo Avionica S.p.A., distribuito dalla TRIMPROBE S.p.A. (ambedue del Gruppo Finmeccanica) fino a gennaio 2008 su licenza di utilizzo brevetto del dr. Clarbruno Vedruccio.
Attualmente � in fase di organizzazione la nuova gestione.

Per aprire i file con estensione PDF � necessario disporre di Adobe Acrobat Reader
Il programma � scaricabile dal sito: http://www.adobe.com/it/products/reader/
o direttamente a questo link: http://get.adobe.com/it/reader/
|